1 optical 2 electrical (unus modus unius fibrarum SC) B-finem summus qualitas metallorum
3-port 10/100M WDM Media Converter Single-modus Singulus-fibra SC)
Product Features:
Introducendis Fibra Optica Converters - Perfecta Solutio pro Industrial Communications
In Huizhou Changfei Optoelectronics Technologiae Co., Ltd., superbi sumus principem opificem professionalis instrumenti communicationis industrialis in Sinis.Nostrum officium innovandi et solvendi qualitates solutiones nobis fidem fecit in industria nomen.Novissimum membrum familiae productum nostrae inducere laetamur - converter opticus exiguum, quod est lusus commutatoris in agro communicationis industrialis.
Parva forma factor fibra opticorum convertentium specialiter ordinatur ad postulationes ambitus industriales.Cum casus ferrei subtilissimi consilio, elegans non solum spectat, sed etiam vetustatem et diuturnam observantiam praestat.Utrum es in fabricandis, oleis et gas, vel quaelibet alia industriae ambitus, hoc convertens est specimen inconsutilem, certae communicationis.
Una ex praestantia notarum fibrarum nostrorum convertentium est facultas tradendi distantias 2-120 km sustentandi.Inde idoneus, idoneus ad tam breves-range ac diuturnos communicationis requisita.Utrum machinas in eadem tabulato vel in diversis aedificiis coniungere debes, hic convertens te texit.
Accedit parva fibra opticorum convertentium temperaturas extremas sustinere possunt.Temperatura operativa range est -20 gradus ad 70 gradus, qui gravissimas condiciones industriales tractare possunt.Sive sit calidum vel frigidum, convertens pergit ad perfectam functionem, continuam communicationem procurans.
Intelligimus momentum status armorum evidenter indicando.Propterea fibra minima convertentium instructa sunt indicibus dynamicis DUXERIT.Hi indices status temporis reales tibi praebent, ut facile monitores ac solutiones quascumque quaestiones oriantur permittas.
Sicut fibra optica industrialis transceivers, minima fibra opticorum convertentium varias optiones connexionis offerunt.Is lineamenta 1 fibra et 2 electricum unum modum fibrarum B-finium unius portuum, tibi flexibilitatem varias machinis connectere ac facile retis tuis amplificare praecipimus.
Cum ad solutiones communicationis industriales advenit, Huizhou Changfei Optoelectronics Technologiae Co., Ltd. particeps electionis est.Cum extenso productum range, incluso permutationes industriales nubis administratae, virgas PoE et virgas Ethernet, conamur solutiones comprehensivas praebere omnibus retis necessariis tuis.
Non solum nobis fabrica, sed tellus servitio completa.Manipulus peritorum noster deditus est ad postulata tua specifica cognoscenda et solutionem sartoris te praebens.Tecum sumus e producto delectu et institutione ad sustentationem permanentem.
In fine, Huizhou Changfei Optoelectronics Technologiae Co., Ltd. convertentium opticorum fibra parva sunt oportet habere pro quavis environment industrialis.Superiore consilio, late tradendo, temperatura resistentia, indicibus DUCTUS perfectam electionem efficit inconsutilem ac certam communicationem.Spera nobis ut particeps essem in communicationibus industrialibus et experire mutationes fructus nostros ad operationes tuas afferre posse.Colamus simul ut futura connexa crearemus!
Quid hoc Product Num
◇ CF-1012SW-20B est centum megabytarum mediarum convertentium, cum centum megabytis RJ-45 portum et portum centum megabytarum SC fibrarum, quae inter signa electrica et optica convertere potest.
Ut hoc Product Works
◇ CF-1012SW-20B WDM (necem divisio multiplex) technologiam adhibet, adiuvans mittendi et recipiendi notitias ad spatium usque ad 20 km cum uno tantum modo fibrarum, quae dimidium funis instruere pretium pro clientibus servat.CF-1012SW-20B notitias ad 1550 um necem transmittit et in 1310 um in fibra optica datam accipit.Ideo fabrica terminalis in coniunctione cum CF-1012SW-20B data ad necem 1310 um mittere debet et notitias ad necem 1550 um recipere.CF FIBERLINK alia media convertens CF-1012SW-20A una est e fructibus quae cooperari possunt cum CF-1012SW-20B.
Aliae Features
◇ Praeter haec media convertens adhiberi potest ut machinam standalone (nulla eculeo requirente) vel adhibita cum eculeo CF FIBERLINK CF-2U14 pro auto MDI/MDI-X in TX portu in quo duplex modus agitur.
Technical Parameter
Exemplar | CF-1012SW-20B | |
Interface Characteres | ||
Certum Portus | 2* 10/ 100Base-TX RJ45 port 1* 155M uplink SC fibra port | |
Aer Portus | X/ 100Base-TX auto- sentientia, plena/dimidii duplex MDI/MDI-X adaptatio sui ipsius | |
Pair retorta Transmissio | 10BASE-T: Cat3,4,5 UTP(≤100 meter) 100BASE-T: Cat5e vel postea UTP(≤100 meter) | |
Optical Portus | Default opticus modulus unus-modus est fibra 20km, SC portum | |
Necem / distantia | A-finem: RX1310nm / RX1550nm 0 ~ 40KM B-end:RX1550nm/RX1310nm 0 ~ 40KM | |
A-finem: RX1490nm / RX1550nm 0 ~ 120KM B-end:RX1550nm/ RX1490nm 0 ~ 120KM | ||
Chip Parameter | ||
Network Protocol | IEEE802.3 10BASE-T, IEEE802.3i 10Base-T, IEEE802.3u 100Base-TX, IEEE802.3u 100Base-FX, IEEE802.3x | |
Transmissio modus | Copia ac Vestibulum (Fil Wire Volo) | |
Capacitas switching | 0.6Gbps | |
Quiddam Memoria | 0.45Mpps | |
MAC | 1K | |
DUXERIT Testimonium | Fibre | SD/SPD1 (viridis) |
rate | SPD2: 10/ 100 (viridis); | |
Data | FX (viridis) / TP (viridis) | |
FDX (viridis) | ||
Unius / duplex | ||
Potestas | PWR (viridis) | |
Potestas | ||
Opus intentione | AC:100-240V | |
Potentia consummatio | Sto<1W, plena onus <3W | |
Potestas Supple | DC:5V/2A potentia industrialis copia | |
Fulmen praesidium & Certification | ||
fulgur praesidium | Protectio fulgur: 4KV 8/20us, Praesidium campester: IP30 | |
Certification | CCC; CE marca, commercial;CE/LVD EN60950;FCC Pars 15 Classis B;RoHS | |
Parameter corporalis | ||
Operatio TEMP | -20~+55°C;5%~90% RH Non condensing | |
Repono TEMP | -40~+85°C;5%~95% RH Non condensans | |
Dimensio (L*W*H) | 94mm* 71mm*27mm | |
Institutionem | Desktop, CF-2U14 tortus socors |
Product Size:
productum application diagra
Quomodo fibram opticam transceiver eligere?
Fibra optica transceivers per 100-metri limitationem funes Aernei in notitia tradenda rumpunt.Magno operando freti mutandi astulas et magnas capacitatis gazas, dum vero transmissionem et commutationes non-obturbantes assequuntur, aequilibrium quoque commercium, solitudo et conflictus praebent.Error deprehensio et alia munera altam securitatem ac stabilitatem in notitia tradenda obtinent.Ergo fibra optica transceiver producta adhuc necessaria erit pars constructionis network actualis diu.Quomodo ergo fibra optica transceivers eligimus?
Munus test 1. Portus
Maxime probandum est an quilibet portus in duplici statu 10Mbps, 100Mbps et semiduplici statui normaliter laborare possit.Eodem tempore, probetur utrum quilibet portus maximam celeritatem transmissionis eligere possit automatice, et automatice cum aliis machinis tradendae ratem inserere.Haec probatio in aliis probatis comprehendi potest.
2. Compatibility test
Maxime probat nexum facultatis inter fibra optica transceiver et alias machinas compatibiles cum Aerneto et Fasti Ethernet (including card retis, HUB, Switch, retis opticis et switch optica).Necessitas products compatibilis nexum sustinere poterit.
3. cable nexum habet
Proba fibra transceiveri optici facultates ad retinacula retiacula sustentanda.Primo, experire nexum capacitatem Categoriae 5 retiacularum retinacula cum longitudinibus 100m et 10m, et proba nexum facultatem longi Categoriae 5 retiacularum reticulorum (120m) diversarum notarum.In probatione, portus opticus transceiveri requiritur ut nexum habeat facultatem 10Mbps et pro 100Mbps, et summum iungi poterit sine erroribus transmissionibus duplicatum 100Mbps.Categoria 3 contorta duo funes non probentur.Subtestinis aliis probatis includi possunt.
4. Characteres tradendi (transmissio damnum rate of notitia facis diversarum longitudinum, celeritas transmissionis)
Hoc maxime probat fasciculum damni infecti, cum fibra transceiver opticus portus opticus varias notitias fasciculos transmittit, et nexum celeritatis sub diversis connexionibus venditis.Ad ratem damni fasciculi, uti potes programmate testi proviso per retis card ad probandum schedulam iacturam faciendam cum fasciculus magnitudo est 64, 512, 1518, 128 (libitum) et 1000 (optional) back sub diversis connexionibus venditis.numerus errorum fasciculi, numerus fasciculorum missorum et receptorum plus quam 2,000,000.Test transmissio celeritatis uti potest ad effectum deducendi, ping et alia programmata.
5. Compatibilitas totius machinae ad network tradenda protocollo
Maxime probat convenientiam fibrarum transceivers opticorum ad protocolla retis, quae probentur in Novellis, Fenestra et aliis ambitibus.Protocolla retis humiliora sequentia ut TCP/IP, IPX, NETBIOS, DHCP, etc. probentur, et protocolla quae iacienda sunt probanda sunt.Transceivers optici requiruntur ad has protocolla (VLAN, QOS, COS, etc.).
6. Testimonium status test
Test num status indicator lucis conveniat cum descriptione tabulae et usoris manualis, et num stat cum statu fibri transcepti optici hodiernam.